SYMBOLS
ELECTRICAL
EXTENSION CORD CABLE SIZE
Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load.
Inadequate size cables can cause a voltage drop, which can damage the appliance and overheat the cord.
Current in
Amperes
Load in Watts Maximum Allowable Cord Length
At 120V At 240V #8 Wire #10 Wire #12 Wire #14 Wire #16 Wire
2.5 300 600 1000 ft. 600 ft. 375 ft. 250 ft.
5 600 1200 500 ft. 300 ft. 200 ft. 125 ft.
7.5 900 1800 350 ft. 200 ft. 125 ft. 100 ft.
10 1200 2400 250 ft. 150 ft. 100 ft. 50 ft.
15 1800 3600 150 ft. 100 ft. 65 ft.
20 2400 4800 175 ft. 125 ft. 75 ft.
25 3000 6000 150 ft. 100 ft.
30 3600 7200 125 ft. 65 ft.
40 4800 9600 90 ft.
FUEL WARNING
No smoking when filling with gasoline. Do not overfill. Full
level is 1 in. below the top of the fuel neck. Stop the engine
for five minutes before refueling to avoid the heat from the
muffler igniting fuel vapors.
ENGINE LUBRICANT
WARNING
You must add lubricant before first
operating the generator. The oil
reservoir capacity is 20 oz. Always
check the lubricant level before each
operation. The lubricant level should
always register between the hatched areas on the dipstick.
The unit is equipped with a sensor which will automatically
shut off the engine if the lubricant level falls below a safe limit.
GROUNDING WARNING
National Electric Code requires generator to be grounded to
an approved earth ground.
Operation of this equipment may create sparks that can start fires
around dry vegetation. A spark arrestor may be required. The operator should contact
local fire agencies for laws or regulations relating to fire prevention requirements.
WARNING
AVERTISSEMENT
L’utilisation de cet équipement peut créer des étincelles
susceptibles d’enflammer la végétation sèche. Il peut être nécessaire d’utiliser un
pare-étincelles. L’utilisateur doit communiquer avec le service local d’incendie pour
connaître toutes les lois et tous les règlements portant sur les exigences en matière
de prévention des incendies.
940947003-03
ADVERTENCIA
El uso de este equipo puede producir chispas propensas a
iniciar incendios cerca de vegetación seca. Es posible que se necesite un parachis-
pas. El operador debe ponerse en contacto con las agencias contra incendios locales
para conocer las leyes y regulaciones relacionadas con los requisitos de prevención
de incendios.
Vista de pagina 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 59 60

Comentarios a estos manuales

Sin comentarios