Logs and Reports
■ Problem: Bin full - the reject bin full sensor has been blocked for longer than 5 seconds and
the transport system has stopped. The bin will need to be emptied before the transport can be
restarted.
o
Action:
If the bin is full:
1. Remove, identify and segregate the product. Once the sensor is unblocked the fault
will automatically clear.
If the bin is not full:
1. Check the Bin full sensor is working correctly.
■ Problem: Link corrupted - data corruption has occurred between the detector and LomaLink
PC or other controlling device. The operation of the detector is unaffected.
o
Action:
1. Check cabling and link connectors from remote device.
2. Check LomaLink PC or other controlling device for reported errors.
■ Problem: Link failure - a break in communication between the detector and LomaLink
PC/other controlling device. The operation of the detector is unaffected.
o
Action:
1. Check cabling and link connectors from remote device.
2. Check connections between the detector and LomaLink PC or other controlling device
for loose or broken wiring/connectors.
■ Problem: PV test timeout - an automated prompt for the PV test has either not been actioned
or completed within the window time set. The transport system may have stopped.
o
Action: Clear system fault (restart the transport if stopped) and perform a PV test.
■ Problem: PEC obstructed - the product registration photo-eye has remained blocked for
greater than 6 consecutive pack lengths. This fault is only generated if the PEC fault is
enabled.
o
Actions:
1. Check the PEC for blockage.
2. Check the PEC is working correctly.
3. Check pack flow length entry is adequate in the Menus > Set Up > Product menu,
ensuring an allowance is made for pack skew.
4. Ensure the correct belt speed is entered in the Menus > Service > Configuration >
System menu..
■ Problem: Wrong flash c/sum - the software has compared the flash checksum currently
stored in its memory with the checksum for recently installed software. This occurs if a
software update has been done and a hardware cold start was not performed after
installation.
o
Action:
1. Perform an update to the Flash Checksum in the Menus > Machine Details menu.